Reverse osmosis membrane gives excellent performance for a wide variety of applications including low-pressure tapwater purification, single-pass seawater desalination, chemical processing, and waste treatment. This membrane exhibits high rejection at low pressures with very stable long-term operation.
Solute | MW | Rejection (%) |
Sodium fluoride NaF1 | 42 | 99 |
Sodium chloride NaCl | 58 | 99 |
Silica SiO2 (50 ppm) | 60 | 60 |
Sodium bicarbonate NaHCO3 | 84 | 99 |
Sodium nitrate NaNO3 | 85 | 97 |
Magnesium chloride MgCl2 | 95 | 99 |
Calcium chloride CaCl2 | 111 | 99 |
Magnesium sulfate MgSO4 | 120 | >99 |
Nickel sulfate NiSO4 | 155 | >99 |
Copper sulfate CuSO4 | 160 | >90 |
Formaldehyde | 30 | 35 |
Methanol | 32 | 25 |
Ethanol | 46 | 70 |
Isopropanol | 60 | 90 |
Urea | 60 | 97 |
Lactic acid (pH 2) | 90 | 94 |
Lactic acid (pH 5) | 90 | 99 |
Lactic acid (pH 5) | 90 | 99 |
Glucose | 180 | 98 |
Sucrose | 342 | 99 |
Chlorinated pesticides (traces) | − | >99 |
Membrane type | Thin-film composite polyamide |
Maximum operating pressure | 1,000 psi (6.9 MPa) |
Maximum operating temperature | 113°F (45°C) |
Free chlorine tolerance | < 0.1 ppm |
pH range, continuous operation | 2 – 11 |
pH range, short-term cleaning (30 min.) | 1 – 13 |